Date: Thu, 28 Mar 2024 15:08:33 +0000 (UTC) Message-ID: <1528550213.117.1711638513251@6bf000190eb4> Subject: Exported From Confluence MIME-Version: 1.0 Content-Type: multipart/related; boundary="----=_Part_116_2083833550.1711638513250" ------=_Part_116_2083833550.1711638513250 Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable Content-Location: file:///C:/exported.html
Install the package directly from the C=
ODESYS user interface:
After installing the package, CODESYS must be restarted.
The package will be installed in the following directory: C:\Users\<use=
rname>\CODESYS Control for PFC200 SL / C:\Users\<username>\CODESYS=
Control for PFC100 SL
To install the CODESYS runtime, open th=
e configuration dialog in T=
ools/Update PFC200/PFC100.
The default user is root and the default password is wago.
You can enter the IP address manually or select the controller via the sca=
n dialog:
If there are multiple versions of the package, then you will have to selec=
t the one you want to install.
If no packages are offered, then the path of the package must be checked a=
nd modified if necessary.
The version can be installed on the fie=
ldbus coupler by clicking the <=
em>Install button.
The version can be viewed by clicking the System info button.=
(The PFC may have to be rebooted by clicking the Reboot target&nbs=
p;button).
=
Establish a connection to the device.
To do this, open the device dialog by double-clicking the device in the tr=
ee:
Open the dialog by clicking the Scan network button. All detected=
devices of the type are listed:
Select the corresponding device by double-clicking it.
=
The last two characters correspond to the last part of the IP address (hex=
adecimal).
CODESYS establishes a connection to the device and reads the device Inform=
ation:
Now login to the device by clicking Online/Login<=
/em>. It is not necessary to start the application.
Open the scan dialog of the K-bus from =
the context menu.
=
After a short time, all detected adapters are listed:
There may be adapters with special subtypes that cannot be resolv=
ed.
In these cases, you can click the ellipsis button to open another dialog w=
here the adapter can be specified:
Now all adapters can be added to the project by clicking the Copy all devices to proj=
ect button.
Logout to the device by clicking <=
span style=3D"color: rgb(49,112,143);">Online/Logou=
t.
Set the outputs and test the input ada=
pters.
In CODESYS, only that data is updated which is used in the p=
rogram.
For testing the adapters, open the PLC Settings tab in the device=
dialog and set Always update variables to Always update variables to Enabled 2 (always in bus cycle task).
Download the modified application to t=
he controller by logging in again and start it by clicking Debug/Start=
em>.
The symbols in the tree should now be green.
In the I/O mapping of the respective adapter (double-click the adapter), y=
ou can set the outputs or view the current values of the input adapter.
=